Admin started the topic LSA in the forum SOLAS 6 years, 6 months ago
Maintanence of LSA equipments as a chief officer
III/20 and III/36
Refer excel sheet
How do you carry out maintenance of lifeboat davit?
Msc circular 1205 – for manual (includes list of checks weekly and monthly)
Maintenance of l/b davit (msc 1093)
1) Davit structure – corrosion, misalignment, deformation, excessive freeplay
2) Wires and sheaves…[Read more] -
Admin started the topic IMDG in the forum Cargo Work 6 years, 6 months ago
Solas II 2-2/ carriage of dg – DOC
– solas VI/2
General principles of loading docs required
– necessary for proper stowage and safe carriage
Cargo units – special properties of cargo,
Css code 1.9
Prior to shipment the shipper should provide all necessary information about the cargo to
enable the shipowner or ship operator to ensure that:
– the…[Read more] -
Admin started the topic EUMRV & IMO DCS in the forum Marine Legislation 6 years, 6 months ago
Purpose: Reduce CO2 emissions.
EUMRV: Eu(rope) Monitoring Reporting Verification
Date: 1 Jan 2018
Ships: > 5,000 gross tonnage (GT)
Area: EU, calling any EU ports.
Report details:
– Amount and emission factor for each type of fuel consumed in total
– Total CO2 emitted and additionally differentiated to aggregated CO2 emitted
-…[Read more] -
Admin started the topic Content Page for drawings & diagrams in the forum Drawings 6 years, 9 months ago
-
Admin started the topic Free surface effect in the forum Miscellaneous 6 years, 10 months ago
Free Surface Effect Of Ships:
When any tank or a compartment is partially filled, the motion of the liquid (due to the ship’s rolling and pitching motions) would reduce the stability of the ship. Why? Because, when the ship is inclined, the liquid in the tank shifts to the lower side of the tank, as shown in the following figure.Figure 1:…[Read more]
-
Admin started the topic Overhead crane checks in the forum Miscellaneous 6 years, 10 months ago
Daily checks
- Check the lubrication
- Check the noise level by operating the crane without load
- Check the heat generation
- Check all the limits and trips are working properly
- Check the contact areas of electrical equipment
- Check the brake operation
- Check condition of clamp in the hook
2)PMS
- Overhauling of motor
…
-
Admin started the topic Zener diode in the forum Electrotech 6 years, 10 months ago
Zener Diode
Definition: A heavily doped semiconductor diode which is designed to operate in reverse direction is known as the Zener diode.Diodes generally are known as a device that allows the flow of current in one direction (forward biased) and offers resistance to the flow of current when used in reverse bias. Zener Diode on the other…[Read more]
-
Admin started the topic Switchboard safeties in the forum Electrotech 6 years, 10 months ago
The Important safety devices fitted on main switch board are:
- Circuit breakers: A circuit breaker is an auto shut down device which activates during an abnormality in the electrical circuit. Especially during overloading or short circuit, the circuit breaker opens the supplied circuit from MSB and thus protects the same. Different circuit…
-
Admin started the topic Low insulation in the forum Electrotech 6 years, 10 months ago
Factors that affect insulation
1) Moisture
- Leakage current increases
2) Dust, oil, deposits on end of winding and connections
- Cause insulation burn out overtime
- Reduce heat dissipation, dust clog
- Ventilation duct and restrict free flow of air
- Increase machine temperature and cause thermal degradation on…
-
Admin started the topic High voltage system isolation in the forum Electrotech 6 years, 10 months ago
Ppe
must be of correct insulating class
-
-
- electrically insulating safety helmet
- insulating rubber gloves
-
must satisfy international IEC standards, subjected to dielectrical, mechanical resistance and ageing test.to check if easily broken
-
-
- Insulating gloves
- Pneumatic glove tester,
- Insulating…
-
-
-
Admin started the topic Air circuit breaker in the forum Electrotech 6 years, 10 months ago
- Air Circuit Breaker (ACB) is used to provide Overcurrent and short-circuit protection.
- Air as an arc extinguishing medium.
Air Circuit Breaker Working
- Air Circuit breakers generally have two pairs of contacts.
- The main pair of contacts (1) carries the current at normal load and these contacts are made of copper metal.
- The…
-
Admin started the topic Preferential trip in the forum Electrotech 6 years, 10 months ago
1) disconnect non essential circuit from main bus bar in case of failure or overload of main supply
2)Example Air con, Ventilation fan Galley equipment
3)Prevent main circuit breaker trip, prevent blackout, overloading of generator
4)Preferential trip circuit consist of electromagnetic coil, arrangement to provide delay to disconnect…[Read more]
-
Admin started the topic Reverse power relay in the forum Electrotech 6 years, 10 months ago
-
-
- The reverse power relay is prevents power from flowing in the reverse direction.
-
-
-
- The relay is used in installations where a generator runs in parallel with another generator
-
-
-
- to prevent power from the bus bar or another generator from flowing back to the active generator when…
-
-
-
Admin started the topic Crankcase explosion & inspection in the forum Main & Aux Engine 6 years, 10 months ago
- For a fire or explosion to take place, there must be heat, oxygen and fuel
-
-
- In the crankcase of the main engine, the oil particles are churned into small
- If a hot spot comes in contact with these small particles, forms mist,
- These particles move towards the colder region inside the crankcase space and when in…
-
-
Admin started the topic Heat treatment in the forum Material 6 years, 10 months ago
5 types of heat treatment are
1) Normalising
– Steel is heated slow to temperature which internal structure takes place
-Sooked at this temperature
-Cooled slowly in air
2) Annealing
– Similar to normalizing
-Different cooling rate are required for different material
-After heating, soaking, steel is cooled…[Read more]
-
Admin started the topic Hot & cold corrosion in the forum Material 6 years, 10 months ago
Corrosion is a primary concern on ships when it comes to burning heavy fuel oil in the marine engines. It can be further described as:
- Hot Corrosion: It occurs due to the presence of Vanadium (Va) and Sodium (Na) in the fuel oil and affects exhaust passage of the engine
- Cold corrosion: It occurs due to the presence of sulphur in fuel oil…
-
Admin started the topic Non-Destructive Testing in the forum Material 6 years, 10 months ago
Nondestructive testing (NDT) is the process of inspecting, testing, or evaluating materials without destroying the serviceability of the part
Visual inspection inspect for high splatter, undercut,bad stop start point, surface crack.
- Surface inspection
- Magnetic particle
- Liquid penetrant
- Internal…
-
Admin started the topic Training junior for scavenge space cleaning in the forum Main & Aux Engine 6 years, 10 months ago
Firstly before on the important of keeping scavenge space clean, safety and risk acessment as the main priority.
- Prior to entering enclose space, risk assessment to be carry out by competent officer
- Potential hazards to be identified. Such as toxic gas.
- The space have to check for oxygen content using gas detector. Oxygen should read…
-
Admin started the topic Lo managment in the forum Fuel Oil, Lub Oil and Water Treatment 6 years, 10 months ago
1) when taking over duties
– As C/E, upon joining vessel check ROB of all grades of Lo for any difference
– Check the daily consumption
-Check for sufficient Lo for voyage
– Check for Lo analysis
2) Ordering of Lubricant
– Take ROB of grade
-Identify economical port
-Check sounding and how much to be…[Read more]
-
Admin started the topic Max liftable bunker in the forum Miscellaneous 6 years, 10 months ago
If office ask for max liftable bunker, 85% of available tank
- voyage – distance, speed, weather, anchorage, port stay
- vessel – Dead weight tonnage, avoid overloading, draft restriction for cargo calculation
- any interal transfer done for ship stability
- as per company policy, 85% volume, no more than…
- Load More