cat60y started the topic Plate heat exhangers Pipings in the forum Heat Exchangers 5 years, 3 months ago
Some observations
that some ships do not have clear indication on inlet or outlet, but in all designs,
Cooling SW/ FW always enters from top and exited from below. ( Cool to hot )
Vice versa the Coolant(JCK or OIL) enters from TOP and exits below. ( Hot to cool )
Helps if you come from a messy piping ship or just tracing pipes. 🙂
-
cat60y replied to the topic Main air compresser problems faced & solutions in the forum Main Air Compressor 5 years, 3 months ago
Tanabe Air compressor, When MAC started, Smoke came out of the crankcasee indicating Blowpass.
initial troubleshootings
1) piston ring brokenChanged all the piston rings and inspection of liner. All okay.
& it turns out there is a broken oring on the piston pin on tanabe MAC, which not everyone knew of or change during major overhaul.
-
cat60y replied to the topic Introduction to A/C and Ref. in the forum Air/Con & Refrigeration 5 years, 3 months ago
All refrigeration system works like this
Compressor( High pressure, Hot gas refrigerant) > Condenser ( High pressure, Cooled liquid refrigerant) > Drier > Thermo expansion valve ( Low pressure, Cold liquid refrigerant) > Evaporator (Heat exchange takes place here, Low pressure, Hot Gas/Liquid refrigerant) > Compressor
Common problems i can…[Read more]
-
cat60y replied to the topic Reverse power relay in the forum Electrotech 5 years, 3 months ago
One of the PSC / Class checks is checking if the reverse power reley is working.
How to check is… to run 2 generator on synchronise.
Changed the switch to manual, reduce the governer on the switchboard to reduce the load until negative. The generator should trip.
-
cat60y's profile was updated 5 years, 3 months ago
-
Admin started the topic Ordering of stores ( valves, pipes, ETC ) in the forum Miscellaneous 5 years, 4 months ago
what is those 10k 40 or 5k 25 marking you see on the valves?
10K – is the pressure limit, 25 is the norminal size of the pipe. Sometimes the valve is too badly corroded to know its marking on the valve itself. A trick is to just look at the system drawing, by right all drawings will indicate the pipe norminal size.
those 15A,25A, 40A,…[Read more]
-
cat60y replied to the topic Preparation for practical jobs in the forum Practical skills 5 years, 4 months ago
Do no scare! Scare no do ! >:)
-
cat60y replied to the topic Thoughts from a senior engineer in the forum Practical skills 5 years, 4 months ago
Slow is smooth, smooth is fast, fast is lethal !
-
Admin started the topic Preparation for practical jobs in the forum Practical skills 5 years, 4 months ago
The practical side is a big learning curve for all marine engineers in their first 3 years or so.
You may or may not had experiences of assisting with overhauling/repairing certain machineries, and now you’re put in the situation of overhauling it as the main engineer in charge. That’s really daunting, we’ve all been through that before.
There’s…[Read more] -
Admin started the topic Scholarship interview prep in the forum Promotional criteria, interview & taking over checklist 5 years, 5 months ago
Based on actual questions:
– Introduce yourself
– Why do you want this scholarship?
– You have completed your National service in January, are you doing anything at the moment?
– Are you attached to any company now?
– What type of vessel(s) do you want to sail?
– What are your stands on time management?
– If there’s a important machines that…[Read more] -
Admin started the topic Helpful Youtube channels/videos in the forum Electrotech 5 years, 5 months ago
-
Admin wrote a new post 5 years, 5 months ago
Hello all, hope everyone is well at home or onboard. Here are the resources, especially for Singapore.
For Singaporean citizens and PRs, it is possible to sign off and return to Singapore regardless of country […]
-
cat60y replied to the topic Jacket water test and treatment in the forum Fuel Oil, Lub Oil and Water Treatment 6 years ago
Understood from the above that Evaporated seawater meaning our distilled water generated from fresh water generator.
Ive only know of 2 chemical suppliers, DREW MARINE & UNITOR
For Unitor, jacket water treatment are using Natfleet to increase Nitrate levels. Nitrate levels are best kept above 1200.
-
cat60y started the topic Fuel oil analysis in the forum Fuel Oil, Lub Oil and Water Treatment 6 years ago
What are the important components to read off the fuel oil analysis chart?
Typically fuel oil analysis are required before using of the fuel oil for the engines, samples will be sent to lab for testing. examples of laboratories( Maritec or viswa lab )
Purpose for fuel oil anaylsis is to adhere to the marpol annex 6, and ensure that proper and…[Read more]
-
cat60y started the topic 2 stroke VS 4 stroke engine in the forum Main & Aux Engine 6 years ago
Let us discuss the differences between 2 vs 4 stroke base on understanding.
2 Stroke engines
– Power, Slow speed. Used for vessel main engine.
– Every 2 stroke of piston movement there is 1 power stroke. ( UP(compression stroke), DOWN(exhaust+ power stroke) )
– 1 exhaust valve
– suction from scavenging ports instead of suction valve.4 Stroke…[Read more]
-
Admin replied to the topic Content Page for drawings & diagrams in the forum Drawings 6 years, 1 month ago
Dear colleagues and friends, If you have better or clearer drawings, do post them up as well.
-
cat60y replied to the topic Air reducer regulator ( control & service air ) in the forum Main Air Compressor 6 years, 1 month ago
If found faulty, some may want to replaced as a whole provided there is a spare.
If not if taking out for cleaning for routine maintenance, cleaning the piston(25), check the condition of the gasket on the valve disk(10).
Make a marking on the body before dismantling, as the center body consists of 2 different holes passage, 1 from inlet to the…[Read more] -
Admin started the topic Air reducer regulator ( control & service air ) in the forum Main Air Compressor 6 years, 1 month ago
We often see this piston type of air reducer onboard for control and service air. Main purpose is to reduce air bottle pressure of around 30 bar to control air, regulating it at 7 bar, or for service air 5 bar.
Maintenance normally is best done at Port if not at Sea by opening the sharing valve between the Control air line and Service air to…[Read more]
-
cat60y started the topic Troubleshooting 3 phase motor, Meggatesting in the forum Electrotech 6 years, 2 months ago
Test can be done through mega tester or a multi meter. There are 2 common test that are carried out on the motor during routine maintenance or suspected motor fault.
1) Low insulation test
This is to make sure that neither of the 3 phases wiring are touching the body of the motor which will result in 440V low…[Read more] -
cat60y replied to the topic 4 Ram Steering Gear in the forum Drawings 6 years, 2 months ago
Isolating valves

In the case of leakage area as shown above, Low low level alarm will be activated. When the alarm is activated, Both isolating valve will be activated & No.1 Lo pump will be switched over to No.2 pump.
4 Rams system work in a Pair. Thus when #4 Ram pipe is leaking, #3 & #4 ram is then isolated.
Through Lo #2 pump and only…[Read more]