icedcappucino replied to the topic Switchboard safeties in the forum Electrotech 2 years ago
Main Switch Board or MSB to be installed on a raised platform.
The location where Switch Board or MSB is installed should have good ventilation, illumination and affected by minimum vibration.
No water or oil pipes should pass above the Switch Board or MSB.
There should be adequate space around allowing comfortable operation ans maintenance.
The…[Read more] -
icedcappucino replied to the topic Switchboard safeties in the forum Electrotech 2 years ago
MSB Safeties
Minimum 3mm rubber mat (approved and certified) in front as well as back of switchboard.
Dead front-end switchboard.
Insulated door handles (Ebonite)
Panel doors are also earthed.
Can’t open door, if breaker is closed.
No pipeline to pass in vicinity.
Minimum 1m free air surrounding switchboard.
Short circuit protection (ACB g…[Read more] -
icedcappucino started the topic Power Factor in the forum Electrotech 2 years ago
-
icedcappucino started the topic Thermostatic Expansion Valve in the forum Air/Con & Refrigeration 2 years ago
-
icedcappucino started the topic Boiler caustic embrittlement in the forum Boilers 2 years ago
Definition of “boiler caustic embrittlement”:
Phenomenon that takes place in boiler when caustic substances gather in materials of the boiler, especially highly stressed regions such as cracks, tube and tube plate connection, joints, bends, and rivets.Definition of “caustic”: Strong corrosive alkaline
Chemical formula:
NA2CO3 = Sodium…[Read more]
-
icedcappucino started the topic Boiler accumulation pressure test in the forum Boilers 2 years ago
Definition:
To test boiler steam pressure does not exceed 10% above WP. In other words, to test that the boiler safety valves are appropriate for the boiler, does it release steam fast enough to prevent steam pressure exceeding 10% above WP.
*Boiler safety valves are set at 3% above WP.So how come it’s possible for boiler steam pressure to…[Read more]
-
icedcappucino replied to the topic How to answer questions in the forum General tips for all 2 years ago
More advice from others:
1. Try to focus more on holding the conversation confidently with the examiner. Which also means concentrate less on thinking is the answer right or wrong.
2. When going for COC 5, the prior experience is just Engine Cadet so the amount of knowledge and experience will naturally be limited. When answering, it’s good…[Read more] -
Admin started the topic Valves in the forum Miscellaneous 2 years, 1 month ago
INTRODUCTION TO VARIOUS VALVES
GLOBE VALVE
Introduction
Globe valve overhaulSCREW DOWN NON RETURN VALVE
Screw down non return valve working principle
Screw down non return valve overhaul -
Admin started the topic Valves in the forum Miscellaneous 2 years, 1 month ago
INTRODUCTION TO VARIOUS VALVES
GLOBE VALVE
Introduction
Globe valve overhaulSCREW DOWN NON RETURN VALVE
Screw down non return valve working principle
Screw down non return valve overhaul -
icedcappucino started the topic Guide to Electrical Insulation Testing in the forum Electrotech 2 years, 1 month ago
Meggar test to insulation test
WHAT IS “Good” insulation?
Every electric wire in your plant – whether it’s in a motor, generator, cable, switch, transformer, etc. – is carefully covered with some form of electrical insulation. The wire itself is usually copper or aluminum, which is known to be a good conductor of the electric current that powe…[Read more] -
icedcappucino started the topic Resume writing in the forum Shore Transitions 2 years, 1 month ago
-
icedcappucino replied to the topic COC 5 (Engine) Oral Questions in the forum COC (Engine) past oral questions 2 years, 1 month ago
Updated with 2022 questions
Unknown examiner (Motor)
– Bilge system: Assignment 008
Draw/explain system
Explain normal operation
Explain Abnormal operation (water rising above bilge wells)
Explain Emergency bilge sea suction
SOLAS requirements for such valve.
Which MARPOL Annex falls under?
Explain/draw Non-return globe valve
Function of compound…[Read more] -
icedcappucino started the topic L.O analysis in the forum Fuel Oil, Lub Oil and Water Treatment 2 years, 1 month ago
Given below is a medium speed trunk type main engine oil analysis report. With reference to each parameter of this report:
• Is there sufficient additive reserve in circulation oil to protect the engine?
• Analyze the condition of this oil from used oil test results for each parameter by comparing with SAE 30 New oil.
• Discuss the effect of conti…[Read more] -
icedcappucino started the topic Enhanced Survey Programme in the forum Marine Legislations and Surveys 2 years, 1 month ago
Lloyd’s Register ESP for Bulk Carriers Preparation for Special Survey
For the purpose of this post, we’ll focus on double skin bulk carriers:
Definitions:
1. Overall survey: Intended to report on overall condition…[Read more] -
Admin started the topic Transom stern construction in the forum Drawings 2 years, 2 months ago
-
Admin started the topic Fore end construction in the forum Drawings 2 years, 2 months ago
-
Admin started the topic Double bottom construction in the forum Drawings 2 years, 2 months ago
-
Admin started the topic General cargo ship midship cross section in the forum Drawings 2 years, 2 months ago
-
Admin started the topic Explosion proof protection concepts in the forum Marine Legislation 2 years, 2 months ago
EX D FLAMEPROOF
Ex d or Flameproof means that an enclosure or junction box is manufactured and certified as explosion proof according to explosion protection concepts.The Flameproof classification is a type of protection in which the parts that can ignite in an explosive atmosphere are placed within an enclosure that can withstand the force…[Read more]
-